Thursday 1 September 2011

Preparation Of Mowiol Mounting Medium

Preparation of Mowiol Coverslip Mounting Solution for Fluorescence Microscopy
This protocol describes the preparation of a coverslip mounting solution called Mowiol. Mowiol (Mowiol 4.88, Calbiochem catalog number 475904) is a solution of polyvinyl alcohol. This solution normally hardens overnight after slide preparation, and does not require the coverslips to be sealed with nail polish. Put 6 g glycerol in a 50 ml plastic centrifuge tube and add a small stir bar.
1. Add 2.4 g Mowiol (Calbiochem); stir to mix.
2. While stirring, add 6 ml distilled water and leave 2 hours at room temperature.
3. Add 12 ml 0.2M Tris (pH 8.5).
4. Add a small amount of NaN3 (Sodium Azide) such that the final concentration is 0.02% (optional).
5. Incubate the tube in hot water (50 – 60ºC) for 10 minutes to dissolve the Mowiol. This can be repeated over several hours if necessary.
6. Centrifuge at 5000 g for 15 minutes to remove any undissolved solids. Store 1ml aliquots in eppendorf tubes at -20ºC.
7. Warm tubes to room temperature for use. Opened tubes can be stored at 4ºC for approximately 1 month. Discard if any crystalline material is seen in the tube or on the slides.
8. Leave cover slipped slides in the dark overnight to harden before oil immersion lenses are used or put at 37oC for about 10 min.
Note: Do not use so much mounting solution that the coverslips are floating. Normally, ~5 µl for a 10mm round coverslip, 15 – 20 µl is sufficient for a 22 x 22 mm coverslip. 22 x 50 mm coverslips require about 40 – 50 µl.

No comments:

Post a Comment